14 points

We ripped out our last gas appliances this fall, a gas furnace and gas fireplace log set. We now heat with a Cold Climate rated heat pump, and put in an electric log set. We actually use the fireplace much more now than we did with gas.

We’re very happy with being a fossil fuel free house now.

permalink
report
reply
14 points

The big problem is that those billions of dollars in savings would cost billions of dollars in profits for energy companies. As long as Citizens United remains in place, we are unlikely to see any legislation to encourage people to switch.

permalink
report
reply
5 points

There are plenty of incentives encouraging people to switch, many coming from the inflation reduction act

permalink
report
parent
reply
2 points

My concern is that I expect those incentives to be removed very quickly under the next administration.

permalink
report
parent
reply
1 point
*

Seriously. I expected to be replacing my gas furnace with heat pump in the next few years, but now I have to figure out if I can or should do it asap

permalink
report
parent
reply
1 point

Time to kiss all that goodbye

permalink
report
parent
reply
8 points

Converted house to a heat pump this year. Never going back.

permalink
report
reply
6 points

My wife and I have been eyeing building a house in the coming years since houses in our area are generally overpriced pieces of shit. I’m an electrician by trade and have a lot of friends in complimentary construction fields, so we’ll ultimately be better off building instead of buying and renovating, especially if we space the build out over a few years.

My plan is radiant floors with an electric boiler, heat pumps in every room, electric instahots at every sink/shower location, with an insanely tight building envelope and a massive solar array. Plus, we save $25k out of the gate going without a natural gas connection. I’d probably still pipe in gas lines just in case.

permalink
report
reply
4 points
*

My plan is radiant floors with an electric boiler, heat pumps in every room with an insanely tight building envelope… Plus, we save $25k out of the gate going without a natural gas connection.

The electric boiler is really attractive especially with the option of using A3 refrigerants. We bought an existing house which already had conventional HVAC ducting and very few A2L heat pumps were available this fall for purchase so we had to buy one of the last R-410a units.

, electric instahots at every sink/shower location,

I looked at that route but the energy efficiency is lower compared to other electric only options. Also the maintenance of descaling multiple times a year wasn’t appealing. We went with a tank-based heat pump water heater to replace the existing electric tank water heater. The energy efficiency has been amazing, and the side benefits of extra cooling and de-humidification in the basement where the unit is was nice.

and a massive solar array.

We put in a 17kW array with 10kWh of battery and its been wonderful so far. We haven’t had an electric bill since a month after installation, with this month being the first since then. If your state/locality has true 1:1 Net Metering, the cost of batteries isn’t worth it from a ROI perspective, but we were interested in not only that, but the backup capabilities in the even of an outage.

permalink
report
parent
reply
2 points

Good to know about the refrigerant, I haven’t even begun to consider different types of systems.

I didn’t think about the descaling, that’s definitely something to consider. My prime consideration with them was a) save on the extra piping, b) not have to wait for hot water to arrive, wasting water in the process (mountains, it gets a bit nippy up here), c) not have to operate a circ pump. I wouldn’t necessarily mind an electric tank WH, I just thought it’d be nifty having instant hot water in each room and not worrying about the tank running empty.

And yeah since we’re building from scratch, I intend on designing the roof with to accommodate as many panels as necessary (I haven’t even begun to do the load calcs for anything yet. In a perfect world, I’d want the front of the house facing north, leaving the entire south side of the house available for solar without cluttering up the curb appeal. Since we don’t have net metering where I’m at, I also have my eye on a battery system primarily for night operation and outages (they’re frequent up here), and as essentially a whole house UPS.

permalink
report
parent
reply
2 points

In a perfect world, I’d want the front of the house facing north, leaving the entire south side of the house available for solar without cluttering up the curb appeal.

This is a good strategy for producing the most electricity, but without net metering, it may not match when you need to use it. Southern facing will give you peak generation at noon. East facing will give you peak production in mid-morning. West facing will give you late afternoon-early evening peak. You can also have parts of your array in all of these directions, if your consumption is fairly even throughout the day.

For HOA reasons, I had to put all 44 panels on the back of my house which faces south-southwest. It was a happy accident that this is also nearly optimized for when we consume the most of our electricity. During the summer, the morning isn’t hot yet so we aren’t running AC much, by high noon we’re generating a really good amount already at the peak of the day heat. By late afternoon-early evening its still very hot and we’re starting to do our cooking and laundry which are larger consumers.

Since we don’t have net metering where I’m at, I also have my eye on a battery system primarily for night operation and outages (they’re frequent up here), and as essentially a whole house UPS.

If you don’t have net metering, make sure you don’t overbuild on your array and waste money. You’ll be producing more electricity than you can use during the daylight hours, and unless you’re buying a mountain of batteries (and batteries are expensive as-is) all that oversupply will go to waste. This is another place where a tank water heater would help you. With the Smart tank water heaters (heat pump or otherwise) you can set them for when they should heat, so you could set it to run while you have excess electricity, essentially a thermal battery.

Do you know if you have “Time of Use” (TOU) options for how you pay for your grid electricity? If so, you could reduce the amount of batteries you need and be able to shave off the most expensive hours (while you run on battery) knowing that your batteries will be close to exhausted most nights, but you’ll recharge them on morning sun.

permalink
report
parent
reply
4 points

Genuine question; how do you prevent freezing pipes in cold climates with instahot taps? AFAIK There’s only so much insulation can do about that (although what i know is pretty little when it comes to plumbing/insulation)

permalink
report
parent
reply
7 points

If your pipes inside the house are freezing, then that means the temperature inside the house is below freezing. That means the house heat is off, in which case you have larger problems.

If the house heat is going to be off for an extended time, you should be shutting off the house water supply and opening your tabs to prevent freezing. That’s the same no matter where your water heating happens.

permalink
report
parent
reply
2 points

Pretty much what the other guy said. In climates where temps get below freezing, you have to keep your thermostat at 45°F minimum (though most do 55), and pipes are generally run above the insulation in the floor joist. Pipes are run in such a way that they are sloped down towards the stop and waste valve (basically a valve below the frost line that cuts off the water supply into the house and also drains the water inside the pipes when shut off once you open all the faucets). Even lines out of a central water heater need to be considered since unless a circ pump is installed and always running, they’ll freeze the same as cold pipes.

permalink
report
parent
reply
4 points

When we built our home a few years ago, we made sure that everything in the house was electric: no gas water heater, no gas stove, and no gas central heating. Our heat pump works phenomenally well, our electricity bills are very manageable, and we don’t have a gas bill, at all. It’s great, I highly recommend it.

permalink
report
reply

News

!news@lemmy.world

Create post

Welcome to the News community!

Rules:

1. Be civil

Attack the argument, not the person. No racism/sexism/bigotry. Good faith argumentation only. This includes accusing another user of being a bot or paid actor. Trolling is uncivil and is grounds for removal and/or a community ban. Do not respond to rule-breaking content; report it and move on.


2. All posts should contain a source (url) that is as reliable and unbiased as possible and must only contain one link.

Obvious right or left wing sources will be removed at the mods discretion. We have an actively updated blocklist, which you can see here: https://lemmy.world/post/2246130 if you feel like any website is missing, contact the mods. Supporting links can be added in comments or posted seperately but not to the post body.


3. No bots, spam or self-promotion.

Only approved bots, which follow the guidelines for bots set by the instance, are allowed.


4. Post titles should be the same as the article used as source.

Posts which titles don’t match the source won’t be removed, but the autoMod will notify you, and if your title misrepresents the original article, the post will be deleted. If the site changed their headline, the bot might still contact you, just ignore it, we won’t delete your post.


5. Only recent news is allowed.

Posts must be news from the most recent 30 days.


6. All posts must be news articles.

No opinion pieces, Listicles, editorials or celebrity gossip is allowed. All posts will be judged on a case-by-case basis.


7. No duplicate posts.

If a source you used was already posted by someone else, the autoMod will leave a message. Please remove your post if the autoMod is correct. If the post that matches your post is very old, we refer you to rule 5.


8. Misinformation is prohibited.

Misinformation / propaganda is strictly prohibited. Any comment or post containing or linking to misinformation will be removed. If you feel that your post has been removed in error, credible sources must be provided.


9. No link shorteners.

The auto mod will contact you if a link shortener is detected, please delete your post if they are right.


10. Don't copy entire article in your post body

For copyright reasons, you are not allowed to copy an entire article into your post body. This is an instance wide rule, that is strictly enforced in this community.

Community stats

  • 14K

    Monthly active users

  • 22K

    Posts

  • 548K

    Comments